9 researched code and status records; 0 require additional model-specific verification. Do not identify parts to replace from a code alone.
oFNormal status
Cooling Off / Demo mode: fans and lights can operate while compressors are off.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Literal lower-case o plus F in the guide. Do not confuse with °F or assign an unrelated refrigerator fault.
Manufacturer / technical referenceLock indicator onNormal status
Control panel is locked to prevent setting changes.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Descriptive state / behavior label unless quoted in source. Not a failed-component error code.
Manufacturer / technical referenceDoor Alarm indicator blinking + audible alarmWarning
Door left open for more than two minutes with Door Alarm enabled.
What to do: Record full model/suffix, serial / controller revision, exact display or LED pattern, zone, temperature and sequence. Follow the matching owner guide. Persistent faults require qualified service; a message does not prove a specific part has failed.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Meaning verified only for this model / control / document generation.
Manufacturer / technical referenceFilter indicator blinking redMaintenance
Replace the deodorizing air filter; reminder is approximately 18 months.
What to do: Follow the exact model maintenance instructions and approved replacement parts. Resetting an indicator does not perform the maintenance.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Air / deodorizer filter, not a drinking-water filter. Interval refers to the cited guide.
Manufacturer / technical referenceSabbath mode selectedNormal status
Special operating mode affects controls / display / lights; automatically ends after 85 hours.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Descriptive state / behavior label unless quoted in source. Not a failed-component error code.
Manufacturer / technical referenceAll zone-select buttons blinking after temperature keyNormal status
No zone was selected before attempting to change its temperature.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Documented control interaction; not a three-sensor failure.
Manufacturer / technical referenceControl display goes dark after door closesNormal status
Automatic display sleep; full display switches off after the documented closed-door interval.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Behavior description; guide gives ten minutes for the entire display. Not proof of loss of electrical power.
Manufacturer / technical reference01 during Auto Door Open sensitivity settingNormal status
Higher pressure sensitivity selected for Auto Door Open.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Leading zero preserved. Temporary setting readout, not error code 01.
Manufacturer / technical reference00 during Auto Door Open sensitivity settingNormal status
Default Auto Door Open pressure sensitivity selected.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Dacor DRW24980*** US three-zone wine column, DA68-03607F-05 02/2026
Scope: Leading zeros preserved. Temporary setting readout, not error code 00.
Manufacturer / technical referenceNo matching record. Recheck the complete model, display characters and the corresponding owner manual.