9 documented records across model families. Filter to find a matching display.
pc -ErFault
Panel/main communication fault
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: DRF36C500** technical guide; exact US revision required
Scope: Selected controls only. Verify full model and document revision.
Owner / technical reference44ErFault
Inverter/main communication fault
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: DRF36C500** technical guide; exact US revision required
Scope: Selected controls only. Verify full model and document revision.
Owner / technical reference46ErFault
I/O expander/main communication fault
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: DRF36C500** technical guide; exact US revision required
Scope: Selected controls only. Verify full model and document revision.
Owner / technical reference52ErFault
Wi-Fi/main communication fault
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: DRF36C500** technical guide; exact US revision required
Scope: Selected controls only. Verify full model and document revision.
Owner / technical referenceO FFNormal status
Cooling Off/shop mode; compressors stopped
Also shown as: O-FF; 0 FF
What to do: Check the exact owner manual to understand or exit this mode.
Applies to: DRF36C500** family
Scope: Selected controls only. Verify full model and document revision.
Owner / technical reference · Owner / technical referenceSabbath indicatorNormal status
Sabbath mode active
What to do: Check the exact owner manual to understand or exit this mode.
Applies to: DRF36C500** family
Scope: Selected controls only. Verify full model and document revision.
Owner / technical reference · Owner / technical referencePeak Demand indicatorNormal status
Energy demand-response state
What to do: Check the exact owner manual to understand or exit this mode.
Applies to: DRF36C500** family
Scope: Selected controls only. Verify full model and document revision.
Owner / technical reference · Owner / technical referenceWater filter icon blinkingMaintenance
Water-filter replacement reminder
What to do: Inspect or replace the specified filter as instructed; then reset its indicator.
Applies to: DRF36C500**
Scope: Selected controls only. Verify full model and document revision.
Owner / technical referenceTemperature digits blinkingWarning
Abnormally high zone temperature
What to do: Record the message; check doors, power and actual temperature. Persistent warming needs service.
Applies to: DRF36C500**; affected zone display
Scope: Selected controls only. Verify full model and document revision.
Owner / technical referenceNo records match your filters. Check the displayed characters or try another model family.