8 researched code and status records; 0 require additional model-specific verification. Do not identify parts to replace from a code alone.
P1 flashingFault
Thermostat / cabinet probe fault.
What to do: Record full model/suffix, serial / controller revision, exact display or LED pattern, zone, temperature and sequence. Follow the matching owner guide. Persistent faults require qualified service; a message does not prove a specific part has failed.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Only digital-controller wine variants in the cited guide; preserve case and steady / flashing context.
Manufacturer / technical referenceP2 flashingFault
Evaporator probe fault.
What to do: Record full model/suffix, serial / controller revision, exact display or LED pattern, zone, temperature and sequence. Follow the matching owner guide. Persistent faults require qualified service; a message does not prove a specific part has failed.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Only digital-controller wine variants in the cited guide; preserve case and steady / flashing context.
Manufacturer / technical referenceHA flashingWarning
Compartment remains beyond its high-temperature alarm preset for more than 30 minutes.
What to do: Record full model/suffix, serial / controller revision, exact display or LED pattern, zone, temperature and sequence. Follow the matching owner guide. Persistent faults require qualified service; a message does not prove a specific part has failed.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Only digital-controller wine variants in the cited guide; preserve case and steady / flashing context.
Manufacturer / technical referenceLA flashingWarning
Compartment remains beyond its low-temperature alarm preset for more than 30 minutes.
What to do: Record full model/suffix, serial / controller revision, exact display or LED pattern, zone, temperature and sequence. Follow the matching owner guide. Persistent faults require qualified service; a message does not prove a specific part has failed.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Only digital-controller wine variants in the cited guide; preserve case and steady / flashing context.
Manufacturer / technical referencedA flashingWarning
Door-open condition.
What to do: Record full model/suffix, serial / controller revision, exact display or LED pattern, zone, temperature and sequence. Follow the matching owner guide. Persistent faults require qualified service; a message does not prove a specific part has failed.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Only digital-controller wine variants in the cited guide; preserve case and steady / flashing context.
Manufacturer / technical referenceCompressor LED steadyNormal status
Compressor output is on.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Descriptive state / behavior label unless quoted in source. Not a failed-component error code.
Manufacturer / technical referenceCompressor LED flashingNormal status
Anti-short-cycle restart delay is active.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Descriptive state / behavior label unless quoted in source. Not a failed-component error code.
Manufacturer / technical referenceDefrost LED steadyNormal status
Defrost is active.
What to do: Check the exact model owner guide and selected setting. Record symptoms that persist after the normal state ends.
Applies to: Perlick HP15W / HP24W / HH24WS / HC24WB / HA24WB, Z2669 05/2023 matching digital control
Scope: Descriptive state / behavior label unless quoted in source. Not a failed-component error code.
Manufacturer / technical referenceNo matching record. Recheck the complete model, display characters and the corresponding owner manual.