15 documented records across model families. Filter to find a matching display.
EC50Fault
Excess refrigerator compressor runtime
Also shown as: EC 50
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: Selected legacy 600/648PRO/700 controls
Scope: Condenser/door/airflow/system checks; not proof of compressor failure.
Manufacturer referenceEC40Fault
Excess freezer compressor runtime
Also shown as: EC 40
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: Legacy 600/648PRO/700 refrigerator/freezer combinations
Scope: Not equivalent to Classic 40 1 40, which concerns refrigerator runtime.
Manufacturer reference40 1 40Fault
Excess refrigerator compressor runtime
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: Classic BI built-in controls
Scope: Preserve all three groups. Not legacy EC40.
Manufacturer reference05Service diagnostic
Refrigerator cabinet sensor fault
Also shown as: EC 05
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24R/RO/C legacy US service platform; matching fitted circuits only
Scope: UC-24 service history; not a universal numeric Sub-Zero code.
Manufacturer reference06Service diagnostic
Refrigerator evaporator sensor fault
Also shown as: EC 06
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24R/RO/C legacy US service platform; matching fitted circuits only
Scope: UC-24 service history; not a universal numeric Sub-Zero code.
Manufacturer reference50Service diagnostic
Excess refrigerator compressor runtime
Also shown as: EC 50
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24R/RO/C legacy US service platform; matching fitted circuits only
Scope: UC-24 service history; not a universal numeric Sub-Zero code.
Manufacturer reference07Service diagnostic
Freezer cabinet sensor fault
Also shown as: EC 07
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer reference08Service diagnostic
Freezer evaporator sensor fault
Also shown as: EC 08
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer reference20Service diagnostic
Defrost underheat plus missing feedback
Also shown as: EC 20
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer reference21Service diagnostic
Defrost overheat
Also shown as: EC 21
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer reference22Service diagnostic
Missing defrost-start voltage feedback
Also shown as: EC 22
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer reference23Service diagnostic
Defrost overheat plus missing feedback
Also shown as: EC 23
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer reference24Service diagnostic
Defrost underheat
Also shown as: EC 24
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer reference40Service diagnostic
Excess freezer compressor runtime
Also shown as: EC 40
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24C refrigerator/freezer only, US legacy platform
Scope: UC-24C service history only; excludes refrigerator-only columns and wine storage.
Manufacturer referenceEEFault
Sensor error in indicated zone
What to do: Photograph display and record full model. Arrange diagnosis if persistent; do not select parts from code alone.
Applies to: UC-24 matching compartment / diagnostic sensor display
Scope: EE alone does not identify which sensor; read zone/test context.
Manufacturer referenceNo records match your filters. Check the displayed characters or try another model family.