18 researched codes and status records; 0 require model-specific verification. A displayed message alone does not identify a replacement part.
F1Fault
Thermal-sensing circuit open.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Generic GE article only. Not a universal code map for Café, Profile or Advantium.
Technical referenceF2Fault
Thermal-sensing circuit shorted.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Generic GE article only. Not a universal code map for Café, Profile or Advantium.
Technical referenceF3Fault
Touchpad circuit shorted.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Generic GE article only. Not a universal code map for Café, Profile or Advantium.
Technical referenceF4Fault
Humidity-sensing circuit open.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Generic GE article only. Not a universal code map for Café, Profile or Advantium.
Technical referenceF5Fault
Humidity-sensing circuit shorted.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Generic GE article only. Not a universal code map for Café, Profile or Advantium.
Technical referenceF6Fault
Temperature-probe circuit shorted.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Generic GE article only. Requires the actual probe / touchscreen feature. Not a universal code map for Café, Profile or Advantium.
Technical referenceF10Fault
Touchscreen circuit shorted.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Generic GE article only. Requires the actual probe / touchscreen feature. Not a universal code map for Café, Profile or Advantium.
Technical referenceProbeWarning
Temperature probe open or unplugged during probe cooking.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Probe-cooking-equipped model only. No inference to a conventional humidity sensor.
Technical reference888Normal status
Power connection or restoration indication.
What to do: Follow the exact owner instructions for this setting or prompt; record details if operation does not match them.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Owner-described state, not a component fault. Display varies by model.
Technical reference8888Normal status
Power connection or restoration indication.
What to do: Follow the exact owner instructions for this setting or prompt; record details if operation does not match them.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Owner-described state, not a component fault. Display varies by model.
Technical referencePFNormal status
Power connection or restoration indication.
What to do: Follow the exact owner instructions for this setting or prompt; record details if operation does not match them.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Owner-described state, not a component fault. Display varies by model.
Technical reference18Fault
Power-watch condition involving the electronic control.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA generic microwave article; matching features / controls, SKU list unspecified
Scope: Source names code 18. Do not invent F18 or transfer to every model.
Technical referenceERRWarning
Sensor cycle interrupted or steam detection timed out.
What to do: Follow sensor-cooking owner instructions; record mode and door-opening sequence.
Applies to: GE Appliances USA microwave drawer guide; brand/SKU list unspecified, matching drawer controls only
Scope: Drawer-support umbrella context only. Does not establish a GE-branded drawer SKU.
Technical referenceSENSOR ERROR - PLEASE CLEARWarning
Sensor cycle interrupted or steam detection timed out.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA microwave drawer guide; brand/SKU list unspecified, matching drawer controls only
Scope: Exact drawer controls only; support article uses this longer message alongside ERR.
Technical referenceLOCNormal status
Drawer control lock active.
What to do: Follow the exact owner instructions for this setting or prompt; record details if operation does not match them.
Applies to: GE Appliances USA microwave drawer guide; brand/SKU list unspecified, matching drawer controls only
Scope: Owner-described state, not a component fault. Display varies by model.
Technical referenceFOODNormal status
Food / door-opening reminder before starting.
What to do: Follow the exact owner instructions for this setting or prompt; record details if operation does not match them.
Applies to: GE Appliances USA microwave drawer guide; brand/SKU list unspecified, matching drawer controls only
Scope: Owner-described state, not a component fault. Display varies by model.
Technical referencePFNormal status
Drawer power interruption indication.
What to do: Follow the exact owner instructions for this setting or prompt; record details if operation does not match them.
Applies to: GE Appliances USA microwave drawer guide; brand/SKU list unspecified, matching drawer controls only
Scope: Owner-described state, not a component fault. Display varies by model.
Technical referenceF3Fault
Key active over 60 seconds or moisture on keypad.
What to do: Record full model/suffix, exact display, mode and sequence. Persistent errors require qualified microwave service using the matching documentation. Do not open the cabinet or select a part from the code alone.
Applies to: GE Appliances USA microwave drawer guide; brand/SKU list unspecified, matching drawer controls only
Scope: Drawer-specific explanation differs from the generic GE shorted-touchpad entry. Model/controller context is required.
Technical referenceNo entries match the search or filters. Verify the exact model, operating mode and displayed characters.