32 researched codes and status messages; 0 require model-specific verification. A code alone is not proof of a failed component.
On/Off LED blinkingFault
Bin thermistor fault indication; open / short / connection condition must be distinguished.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed
Scope: Meaning verified only in this source / control context; do not transfer between model families.
Manufacturer / technical referenceOn/Off + Max Ice LEDs blinkingFault
Harvest failure indication.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed
Scope: Meaning verified only in this source / control context; do not transfer between model families.
Manufacturer / technical referenceStep 2: On/Off LED steadyNormal status
Bin thermistor passes the diagnostic check.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 2
Scope: Steady LED only inside the named service step; not an ordinary-panel status interpretation.
Manufacturer / technical referenceStep 2: On/Off LED 2 blinksService fault
Bin thermistor circuit reported open.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 2
Scope: The named step and LED are essential. The same flash count outside this service step has no assigned meaning here.
Manufacturer / technical referenceStep 2: On/Off LED 4 blinksService fault
Bin thermistor circuit reported shorted.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 2
Scope: The named step and LED are essential. The same flash count outside this service step has no assigned meaning here.
Manufacturer / technical referenceStep 3: Clean LED steadyNormal status
Evaporator thermistor passes the diagnostic check.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 3
Scope: Steady LED only inside the named service step; not an ordinary-panel status interpretation.
Manufacturer / technical referenceStep 3: Clean LED 2 blinksService fault
Evaporator thermistor circuit reported open.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 3
Scope: The named step and LED are essential. The same flash count outside this service step has no assigned meaning here.
Manufacturer / technical referenceStep 3: Clean LED 4 blinksService fault
Evaporator thermistor circuit reported shorted.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 3
Scope: The named step and LED are essential. The same flash count outside this service step has no assigned meaning here.
Manufacturer / technical referenceStep 4: Max Ice LED steadyNormal status
Unit thermistor passes the diagnostic check.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 4
Scope: Steady LED only inside the named service step; not an ordinary-panel status interpretation.
Manufacturer / technical referenceStep 4: Max Ice LED 2 blinksService fault
Unit thermistor circuit reported open.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 4
Scope: The named step and LED are essential. The same flash count outside this service step has no assigned meaning here.
Manufacturer / technical referenceStep 4: Max Ice LED 4 blinksService fault
Unit thermistor circuit reported shorted.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service diagnostic Step 4
Scope: The named step and LED are essential. The same flash count outside this service step has no assigned meaning here.
Manufacturer / technical referenceStep 5: Max Ice LED steadyNormal status
Fill diagnostic detects a full reservoir.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service Step 5
Scope: Owner-described state or setting. Descriptive LED / behavior labels are not asserted to be literal text on the display.
Manufacturer / technical referenceStep 5: Max Ice LED blinkingNormal status
Fill diagnostic detects an empty reservoir; this result alone does not prove a failed valve.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service Step 5
Scope: Owner-described state or setting. Descriptive LED / behavior labels are not asserted to be literal text on the display.
Manufacturer / technical referenceStep 10: Max Ice LED 2 blinksNormal status
Thin ice-thickness setting.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service Step 10
Scope: Configuration readout inside the ice-thickness step; not a thermistor or motor fault code.
Manufacturer / technical referenceStep 10: Max Ice LED 4 blinksNormal status
Normal ice-thickness setting.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service Step 10
Scope: Configuration readout inside the ice-thickness step; not a thermistor or motor fault code.
Manufacturer / technical referenceStep 10: Max Ice LED 6 blinksNormal status
Thick ice-thickness setting.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid standalone clear ice control matching W10761657B, 120 V; compatible SKUs not listed; service Step 10
Scope: Configuration readout inside the ice-thickness step; not a thermistor or motor fault code.
Manufacturer / technical referenceCleaning Needed / Cleaning Cycle illuminatedMaintenance
Cleaning is required.
What to do: Follow the exact model cleaning / filter instructions and use approved supplies. A reminder alone does not establish a component fault.
Applies to: KitchenAid USA standalone ice maker with matching cleaning / filter-equipped control; SKU list not enumerated
Scope: Model-specific owner prompt; does not establish a failed component.
Manufacturer / technical referenceClean light blinkingMaintenance
Cleaning is running OR the cycle was interrupted; determine the actual sequence.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid USA standalone ice maker with matching cleaning / filter-equipped control; SKU list not enumerated
Scope: Source permits more than one cleaning context; blinking alone does not establish a failed component.
Manufacturer / technical referenceCleaning CompleteNormal status
Cleaning cycle completed.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid USA standalone ice maker with matching cleaning / filter-equipped control; SKU list not enumerated
Scope: Owner-described state or setting. Descriptive LED / behavior labels are not asserted to be literal text on the display.
Manufacturer / technical referenceReplace Filter lightMaintenance
Filter replacement reminder based on elapsed time / water throughput.
What to do: Follow the exact model cleaning / filter instructions and use approved supplies. A reminder alone does not establish a component fault.
Applies to: KitchenAid USA standalone ice maker with matching cleaning / filter-equipped control; SKU list not enumerated
Scope: Source specifies nine months / 2,000 gallons on matching controls; not a direct water-quality reading or a universal interval.
Manufacturer / technical referenceReplace Filter flashing after replacementMaintenance
Filter installation / seating condition may need attention.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid USA standalone ice maker with matching cleaning / filter-equipped control; SKU list not enumerated
Scope: Applies to flashing after filter replacement in this support context; do not substitute GE UNC15 reminder meanings.
Manufacturer / technical referenceE0Normal status
Service Test 56 reports no active ice maker errors.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 56
Scope: Service Test 56 only. Not a standalone-machine code and not asserted to appear as an ordinary customer-panel fault.
Manufacturer / technical referenceE1Service fault
Ice compartment failed to reach the target temperature before timeout; cooling / fan issue possible.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 56
Scope: Service Test 56 only. Not a standalone-machine code and not asserted to appear as an ordinary customer-panel fault.
Manufacturer / technical referenceE2Service fault
Ice maker motor failed to find the home position within the permitted harvest attempts.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 56
Scope: Service Test 56 only. Not a standalone-machine code and not asserted to appear as an ordinary customer-panel fault.
Manufacturer / technical referenceE3Service fault
Ice mold heater exceeded the permitted heating time without reaching its target.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 56
Scope: Service Test 56 only. Not a standalone-machine code and not asserted to appear as an ordinary customer-panel fault.
Manufacturer / technical referenceE4Service fault
Dry cycles detected; fill valve / frozen fill tube are possible causes.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 56
Scope: Service Test 56 only. Not a standalone-machine code and not asserted to appear as an ordinary customer-panel fault.
Manufacturer / technical referenceE5Service fault
Ice maker mold thermistor fault condition reported.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 56
Scope: Service Test 56 only. Not a standalone-machine code and not asserted to appear as an ordinary customer-panel fault.
Manufacturer / technical reference01Normal status
Service Test 15: ice bin is full OR not present.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 15
Scope: Leading zero preserved. Full and missing-bin conditions share this result; no assumption of a failed level sensor.
Manufacturer / technical reference02Normal status
Service Test 15: ice bin is not full.
What to do: Check the selected mode and actual operating condition against the model owner guide. Record any symptom that persists after the normal condition ends.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 15
Scope: Leading zero preserved. This is a bin-state diagnostic result, not a generic 02 error.
Manufacturer / technical referenceTest 57: digit 2 = 2Service fault
Harvest not completed after the 70-second diagnostic timeout.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 57
Scope: Digit 2 is the result; digit 1 is sequence state. Do not interpret this as ordinary display code 2.
Manufacturer / technical referenceTest 58: digit 2 = 2Service fault
Ice maker thermistor circuit reported open.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 58
Scope: Digit 1 is heater state; digit 2 is the thermistor result. No service-test entry procedure is supplied for customers.
Manufacturer / technical referenceTest 58: digit 2 = 3Service fault
Ice maker thermistor circuit reported shorted.
What to do: Record full model/suffix, control revision, complete code / LED cadence, mode and sequence. Use the matching owner guide. Persistent faults require qualified service; the indication does not prove one part has failed.
Applies to: KitchenAid refrigerator compartment ice maker, tech sheet W11509412A; matching control, SKU list unspecified; Test 58
Scope: Digit 1 is heater state; digit 2 is the thermistor result. No service-test entry procedure is supplied for customers.
Manufacturer / technical referenceNo matching records. Check the model, display characters or beep/LED pattern and the matching owner guide.